Skip Navigation
Skip to contents

Urogenit Tract Infect : Urogenital Tract Infection

OPEN ACCESS

Articles

Page Path
HOME > Urogenit Tract Infect > Volume 20(2); 2025 > Article
Original Article Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study
Young Kyu Han1orcid , Jeong Woo Lee2orcid , Hae-Il Park3orcid , Jin Bong Choi1orcid
Urogenital Tract Infection 2025;20(2):107-113.
DOI: https://doi.org/10.14777/uti.2550022011
Published online: August 31, 2025
Corresponding author:  Jin Bong Choi,
Email: cjb0812@catholic.ac.kr
Received: 10 May 2025   • Revised: 5 July 2025   • Accepted: 22 July 2025
prev next
  • 9 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

Purpose
To evaluate the diagnostic performance of the Sysmex UF-5000 flow cytometer in detecting acute bacterial prostatitis (ABP) compared to standard urine culture. Materials and Methods: This retrospective study analyzed 45 urine samples from patients with a clinical diagnosis of ABP. Each sample was evaluated using the UF-5000 to measure red blood cells (RBC), white blood cells (WBC), and bacterial counts, and the results were compared with those from standard urine culture and Gram staining. Receiver operating characteristic curves were generated, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value were determined. Concordance between Gram classification by the UF-5000 and conventional Gram staining was also evaluated.
Results
Of the 45 patients, 84.4% had positive urine cultures. The bacterial count parameter demonstrated the highest diagnostic performance (area under the curve [AUC]=0.79; sensitivity, 89.5%; PPV, 91.9%), outperforming WBC (AUC=0.76) and RBC (AUC=0.55). The Gram classification flag showed an overall concordance of 85.7% with conventional Gram staining, with a concordance rate of 88% for Gram-negative organisms.
Conclusions
The Sysmex UF-5000 exhibited good concordance with urine culture for patients with ABP, particularly through the bacterial count parameter. Although it does not replace culture, the UF-5000 may serve as a rapid adjunctive tool to support early clinical decision-making in suspected ABP cases.

  • Cite
    CITE
    export Copy Download
    Close
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study
    Urogenit Tract Infect. 2025;20(2):107-113.   Published online August 31, 2025
    Close

Urogenit Tract Infect : Urogenital Tract Infection
Close layer
TOP