Letter to the Editor A Commentary on “Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study”
Dong-Hoon Lim
Urogenital Tract Infection 2025;20(3):173-174.
DOI: https://doi.org/10.14777/uti.2550044022
Published online: December 31, 2025

Department of Urology, School of Medicine, Chosun University, Gwangju, Korea

Corresponding author: Dong-Hoon Lim Department of Urology, School of Medicine, Chosun University, 365 Pilmun-daero, Dong-gu, Gwangju 61453, Korea Email: dhlim@chosun.ac.kr
• Received: November 20, 2025   • Accepted: November 30, 2025

Copyright © Korean Association of Urogenital Tract Infection and Inflammation

This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 163 Views
  • 7 Download
prev
See the article "Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study" on page 107.
I read with great interest the article by Han et al. [1] evaluating the diagnostic performance of the Sysmex UF-5000 for acute bacterial prostatitis (ABP). Prompt and accurate diagnostic support is essential for this condition, and the authors have contributed valuable data demonstrating the potential usefulness of rapid urine flow cytometry in clinical decision-making. Their findings regarding the bacterial count and Gram classification functions are particularly noteworthy and add meaningful context to the expanding role of automated urinalysis in urological infections.
I would like to respectfully offer 2 suggestions that may help strengthen future research in this area.
First, the cutoff values employed for UF-5000 parameters were determined retrospectively using receiver operating characteristic curve analysis. While this is an appropriate exploratory approach, there remains the possibility of overfitting, especially given the relatively small cohort analyzed [2]. A prospective validation study in an independent population would help confirm the robustness of these proposed thresholds and support broader adoption in routine clinical practice.
Second, although the study demonstrated an encouraging Gram classification concordance rate of 85.7%, further characterization of discordant results may provide useful clinical insights. Differences in bacterial morphology, mixed infections, or low bacterial counts could influence misclassification. A deeper understanding of such scenarios would help clinicians better interpret flagged results and recognize potential limitations when distinguishing between Gram-positive and Gram-negative pathogens.
Overall, the authors should be congratulated for conducting a clinically relevant and methodologically sound pilot investigation. Their balanced discussion and recognition of remaining questions provide a strong basis for future multicenter studies aimed at refining and validating the role of automated flow cytometry in ABP diagnosis.

Conflict of Interest

The author has nothing to disclose.

  • 1. Han YK, Lee JW, Park HI, Choi JB. Diagnostic utility of the Sysmex UF-5000 flow cytometer in acute bacterial prostatitis: a retrospective pilot study. Urogenit Tract Infect 2025;20:107-13.ArticlePDF
  • 2. Unal I. Defining an optimal cut-point value in ROC analysis: an alternative approach. Comput Math Methods Med 2017;2017:3762651.ArticlePubMedPMCPDF

Figure & Data

REFERENCES

    Citations

    Citations to this article as recorded by  

      • ePub LinkePub Link
      • Cite
        CITE
        export Copy Download
        Close
        Download Citation
        Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

        Format:
        • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
        • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
        Include:
        • Citation for the content below
        A Commentary on “Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study”
        Urogenit Tract Infect. 2025;20(3):173-174.   Published online December 31, 2025
        Close
      • XML DownloadXML Download
      Related articles
      A Commentary on “Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study”
      A Commentary on “Diagnostic Utility of the Sysmex UF-5000 Flow Cytometer in Acute Bacterial Prostatitis: A Retrospective Pilot Study”

      Urogenit Tract Infect : Urogenital Tract Infection
      Close layer
      TOP