Skip Navigation
Skip to contents

Urogenit Tract Infect : Urogenital Tract Infection

OPEN ACCESS

Articles

Page Path
HOME > Korean J Urogenit Tract Infect Inflamm > Volume 9(2); 2014 > Article
Original Article Evaluation of Clinical Sample for Accupower UU Real-Time PCR Kit
Seung Ki Min, Soon Ki Kim, Yoo Seok Kim, In-Chang Cho, Gyeong In Lee

임상검체를 이용한 <EM>Accupower</EM> UU Real-Time PCR Kit의 평가
민승기, 김순기, 김유석, 조인창, 이경인
Urogenital Tract Infection 2014;9(2):99-103.

Published online: October 31, 2014
Departments of Urology and <SUP>1</SUP>Laboratory Medicine, National Police Hospital, Seoul, Korea

국립경찰병원 비뇨기과, <SUP>1</SUP>진단검사의학과
Received: 3 October 2014   • Revised: 22 October 2014   • Accepted: 22 October 2014
prev next
  • 11 Views
  • 0 Download
  • 0 Crossref
  • 0 Scopus
prev next

Purpose
In recent years, various diagnostic methods, including culture, immunological detection, conventional polymerase chain reaction (PCR) based methods, and microarray experiment have been applied for detection of Mycoplasma genitalium and Ureaplasma urealyticum infection. We assayed results of real time PCR and culture of variable clinical samples and evaluated various diagnostic indexes for assessing the clinical usefulness of the Accupower UU Real-Time PCR Kit (Bioneer Corp.) for detection of U. urealyticum/parvum. Materials and Methods: We surveyed 111 results of culture test and antibiotic sensitivity test of Ureaplasma spp. that were requested to the department of laboratory medicine, National Police Hospital from January to April 2011. The specimens of Ureaplasma spp. were collected from 97 uterine cervical swab samples, 13 urine samples, and one expressed prostate secretion sample. Real-time PCR and culture methods were performed using the Accupower UU Real-Time PCR Kit (Bioneer Corp.) and Mycoplasma IST2 Kit (BioM&eacute;rieux). Results: The real-time PCR results showed that 80 clinical specimens were infected with U. urealyticum/parvum. These results were compared with those confirmed by microbiological culture. Compared with the culture, the diagnostic indexes (sensitivity, specificity, positive predictive value, and negative predictive value) of Accupower UU Real-Time PCR were 88.6%, 38.8%, 48.8%, and 83.9%, and the concordance between the Accupower UU Real-Time PCR Kit and the microbiological culture method was 58.5%. Conclusions: Accupower UU Real-Time PCR is a very valuable technique which can process analysis of a massive number of samples with high speed, high sensitivity and specificity, and a high detection rate, particularly for Ureaplasma spp.

  • Cite
    CITE
    export Copy Download
    Close
    Download Citation
    Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

    Format:
    • RIS — For EndNote, ProCite, RefWorks, and most other reference management software
    • BibTeX — For JabRef, BibDesk, and other BibTeX-specific software
    Include:
    • Citation for the content below
    Evaluation of Clinical Sample for <EM>Accupower</EM> UU Real-Time PCR Kit
    Korean J Urogenit Tract Infect Inflamm. 2014;9(2):99-103.   Published online October 31, 2014
    Close

Urogenit Tract Infect : Urogenital Tract Infection
Close layer
TOP